TY - JOUR
T1 - Use of integrated real-time continuous glucose monitoring/insulin pump system in children and adolescents with type 1 diabetes
T2 - A 3-year follow-up study
AU - Scaramuzza, Andrea E.
AU - Iafusco, Dario
AU - Rabbone, Ivana
AU - Bonfanti, Riccardo
AU - Lombardo, Fortunato
AU - Schiaffini, Riccardo
AU - Buono, Pietro
AU - Toni, Sonia
AU - Cherubini, Valentino
AU - Zuccotti, Gian Vincenzo
PY - 2011/2/1
Y1 - 2011/2/1
N2 - Background: Insulin pumps and real-time continuous glucose monitoring devices have recently been combined into the sensor-augmented pump (SAP) system. The objective of this study was the evaluation of the clinical use of SAP in a large series of children with type 1 diabetes using insulin pump therapy. Methods: A questionnaire was administered in all pediatric diabetologic centers in Italy; data were analyzed only regarding patients 18 years old or younger and using SAP for 6 months or more. Results: Among all patients using an insulin pump, 129 (13.5 ± 3.8 years old, with a disease duration of 6.3 ± 3.4 years) have been using SAP for 1.4 ± 0.7 years. Four hundred ninety-three patients (12.9 ± 3.4 years old, with a disease duration of 6.2 ± 3.3 years) using conventional insulin pump therapy for 1.7 ± 0.5 years have been evaluated as the control group. After 0.5-3 years of using SAP or conventional insulin pump therapy, glycosylated hemoglobin significantly improved (8.0 ± 1.5% vs. 7.4 ± 0.8% [P = 0.002] and 8.0 ± 1.6% vs. 7.7 ± 1.1% [P = 0.006], respectively); the improvement was higher with SAP (P = 0.005). Insulin requirement showed a significant decrease only in SAP patients (0.88 ± 0.25 vs. 0.7 ± 0.23?U/kg/day, P = 0.003). Body mass index did not change during the observation period. No diabetic ketoacidosis episodes were observed during the follow-up, and severe hypoglycemia significantly decreased in SAP patients (P = 0.04). Conclusions: The increased availability of continuous glucose sensors is likely to have a significant impact on pediatric diabetes therapy and education in the near future. In daily settings, patients using SAP can achieve a better control than patients using conventional insulin pump.
AB - Background: Insulin pumps and real-time continuous glucose monitoring devices have recently been combined into the sensor-augmented pump (SAP) system. The objective of this study was the evaluation of the clinical use of SAP in a large series of children with type 1 diabetes using insulin pump therapy. Methods: A questionnaire was administered in all pediatric diabetologic centers in Italy; data were analyzed only regarding patients 18 years old or younger and using SAP for 6 months or more. Results: Among all patients using an insulin pump, 129 (13.5 ± 3.8 years old, with a disease duration of 6.3 ± 3.4 years) have been using SAP for 1.4 ± 0.7 years. Four hundred ninety-three patients (12.9 ± 3.4 years old, with a disease duration of 6.2 ± 3.3 years) using conventional insulin pump therapy for 1.7 ± 0.5 years have been evaluated as the control group. After 0.5-3 years of using SAP or conventional insulin pump therapy, glycosylated hemoglobin significantly improved (8.0 ± 1.5% vs. 7.4 ± 0.8% [P = 0.002] and 8.0 ± 1.6% vs. 7.7 ± 1.1% [P = 0.006], respectively); the improvement was higher with SAP (P = 0.005). Insulin requirement showed a significant decrease only in SAP patients (0.88 ± 0.25 vs. 0.7 ± 0.23?U/kg/day, P = 0.003). Body mass index did not change during the observation period. No diabetic ketoacidosis episodes were observed during the follow-up, and severe hypoglycemia significantly decreased in SAP patients (P = 0.04). Conclusions: The increased availability of continuous glucose sensors is likely to have a significant impact on pediatric diabetes therapy and education in the near future. In daily settings, patients using SAP can achieve a better control than patients using conventional insulin pump.
UR - https://www.scopus.com/pages/publications/79551614547
U2 - 10.1089/dia.2010.0119
DO - 10.1089/dia.2010.0119
M3 - Article
SN - 1520-9156
VL - 13
SP - 99
EP - 103
JO - Diabetes Technology and Therapeutics
JF - Diabetes Technology and Therapeutics
IS - 2
ER -