TY - JOUR
T1 - Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage
AU - Naldi, Andrea
AU - Pivetta, Emanuele
AU - Coppo, Lorenzo
AU - Cantello, Roberto
AU - Comi, Cristoforo
AU - Stecco, Alessandro
AU - Cerrato, Paolo
AU - Lesmeister, Martin
AU - Lochner, Piergiorgio
N1 - Publisher Copyright:
© 2019 by the American Society of Neuroimaging
PY - 2019/5/1
Y1 - 2019/5/1
N2 - BACKGROUND AND PURPOSE: Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS: A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS: Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] =.70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P <.01), as well as RI (.79 [.11] vs.77 [.03] and.80 [.06] vs.75 [.35]; P =.01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P =.02). CONCLUSIONS: Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
AB - BACKGROUND AND PURPOSE: Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS: A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS: Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] =.70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P <.01), as well as RI (.79 [.11] vs.77 [.03] and.80 [.06] vs.75 [.35]; P =.01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P =.02). CONCLUSIONS: Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
KW - intracerebral hemorrhage
KW - intracranial pressure
KW - optic nerve sheath diameter
KW - retinal vessels
UR - http://www.scopus.com/inward/record.url?scp=85061056807&partnerID=8YFLogxK
U2 - 10.1111/jon.12604
DO - 10.1111/jon.12604
M3 - Article
SN - 1051-2284
VL - 29
SP - 394
EP - 399
JO - Journal of Neuroimaging
JF - Journal of Neuroimaging
IS - 3
ER -