Salta alla navigazione principale Salta alla ricerca Salta al contenuto principale

The Role of Lung Ultrasound Monitoring in Early Detection of Ventilator-Associated Pneumonia in COVID-19 Patients: A Retrospective Observational Study

  • Silvia Mongodi
  • , Nello De Vita
  • , Giulia Salve
  • , Silvia Bonaiti
  • , Francesco Daverio
  • , Margherita Cavagnino
  • , Gilda Siano
  • , Alessandro Amatu
  • , Giuseppe Maggio
  • , Valeria Musella
  • , Catherine Klersy
  • , Rosanna Vaschetto
  • , Belaid Bouhemad
  • , Francesco Mojoli

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

Specific lung ultrasound signs combined with clinical parameters allow for early diagnosis of ventilator-associated pneumonia in the general ICU population. This retrospective cohort study aimed to determine the accuracy of lung ultrasound monitoring for ventilator-associated pneumonia diagnosis in COVID-19 patients. Clinical (i.e., clinical pulmonary infection score) and ultrasound (i.e., presence of consolidation and a dynamic linear–arborescent air bronchogram, lung ultrasound score, ventilator-associated lung ultrasound score) data were collected on the day of the microbiological sample (pneumonia-day) and 48 h before (baseline) on 55 bronchoalveolar lavages of 33 mechanically-ventilated COVID-19 patients who were monitored daily with lung ultrasounds. A total of 26 samples in 23 patients were positive for ventilator-associated pneumonia (pneumonia cases). The onset of a dynamic linear–arborescent air bronchogram was 100% specific for ventilator-associated pneumonia. The ventilator-associated lung ultrasound score was higher in pneumoniacases (2.5 (IQR 1.0 to 4.0) vs. 1.0 (IQR 1.0 to 1.0); p < 0.001); the lung ultrasound score increased from baseline in pneumonia-cases only (3.5 (IQR 2.0 to 6.0) vs. −1.0 (IQR −2.0 to 1.0); p = 0.0001). The area under the curve for clinical parameters, ventilator-associated pneumonia lung ultrasound score, and lung ultrasound score variations were 0.472, 0.716, and 0.800, respectively. A newly appeared dynamic linear–arborescent air bronchogram is highly specific for ventilator-associated pneumonia in COVID-19 patients. A high ventilator-associated pneumonia lung ultrasound score (or an increase in the lung ultrasound score) orients to ventilator-associated pneumonia.

Lingua originaleInglese
Numero di articolo3001
RivistaJournal of Clinical Medicine
Volume11
Numero di pubblicazione11
DOI
Stato di pubblicazionePubblicato - 1 giu 2022

Fingerprint

Entra nei temi di ricerca di 'The Role of Lung Ultrasound Monitoring in Early Detection of Ventilator-Associated Pneumonia in COVID-19 Patients: A Retrospective Observational Study'. Insieme formano una fingerprint unica.

Cita questo