TY - JOUR
T1 - The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients
AU - Beurton, A
AU - Teboul, J-L
AU - GAVELLI, Francesco
AU - FA, Gonzalez
AU - Girotto, V
AU - Galarza, L
AU - Anguel, N
AU - Richard, C
AU - Monnet, X.
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019
Y1 - 2019
N2 - Background: A passive leg raising (PLR) test is positive if the cardiac index (CI) increased by > 10%, but it requires a direct measurement of CI. On the oxygen saturation plethysmographic signal, the perfusion index (PI) is the ratio between the pulsatile and the non-pulsatile portions. We hypothesised that the changes in PI could predict a positive PLR test and thus preload responsiveness in a totally non-invasive way. Methods: In patients with acute circulatory failure, we measured PI (Radical-7) and CI (PiCCO2) before and during a PLR test and, if decided, before and after volume expansion (500-mL saline). Results: Three patients were excluded because the plethysmography signal was absent and 3 other ones because it was unstable. Eventually, 72 patients were analysed. In 34 patients with a positive PLR test (increase in CI ≥ 10%), CI and PI increased during PLR by 21 ± 10% and 54 ± 53%, respectively. In the 38 patients with a negative PLR test, PI did not significantly change during PLR. In 26 patients in whom volume expansion was performed, CI and PI increased by 28 ± 14% and 53 ± 63%, respectively. The correlation between the PI and CI changes for all interventions was significant (r = 0.64, p < 0.001). During the PLR test, if PI increased by > 9%, a positive response of CI (≥ 10%) was diagnosed with a sensitivity of 91 (76-98%) and a specificity of 79 (63-90%) (area under the receiver operating characteristics curve 0.89 (0.80-0.95), p < 0.0001). Conclusion: An increase in PI during PLR by 9% accurately detects a positive response of the PLR test. Trial registration: ID RCB 2016-A00959-42. Registered 27 June 2016.
AB - Background: A passive leg raising (PLR) test is positive if the cardiac index (CI) increased by > 10%, but it requires a direct measurement of CI. On the oxygen saturation plethysmographic signal, the perfusion index (PI) is the ratio between the pulsatile and the non-pulsatile portions. We hypothesised that the changes in PI could predict a positive PLR test and thus preload responsiveness in a totally non-invasive way. Methods: In patients with acute circulatory failure, we measured PI (Radical-7) and CI (PiCCO2) before and during a PLR test and, if decided, before and after volume expansion (500-mL saline). Results: Three patients were excluded because the plethysmography signal was absent and 3 other ones because it was unstable. Eventually, 72 patients were analysed. In 34 patients with a positive PLR test (increase in CI ≥ 10%), CI and PI increased during PLR by 21 ± 10% and 54 ± 53%, respectively. In the 38 patients with a negative PLR test, PI did not significantly change during PLR. In 26 patients in whom volume expansion was performed, CI and PI increased by 28 ± 14% and 53 ± 63%, respectively. The correlation between the PI and CI changes for all interventions was significant (r = 0.64, p < 0.001). During the PLR test, if PI increased by > 9%, a positive response of CI (≥ 10%) was diagnosed with a sensitivity of 91 (76-98%) and a specificity of 79 (63-90%) (area under the receiver operating characteristics curve 0.89 (0.80-0.95), p < 0.0001). Conclusion: An increase in PI during PLR by 9% accurately detects a positive response of the PLR test. Trial registration: ID RCB 2016-A00959-42. Registered 27 June 2016.
UR - https://iris.uniupo.it/handle/11579/197788
U2 - 10.1186/s13054-019-2306-z
DO - 10.1186/s13054-019-2306-z
M3 - Article
SN - 1364-8535
VL - 23
SP - 19
JO - Critical Care
JF - Critical Care
IS - 1
ER -