Abstract
The aim of this study is to compare the surface tension of four common endodontic irrigants: Moltendo EDTA 17%, Cetrexidin, Smear Clear, Sodium hypochlorite 5.25%, with the surface tension of MTAD and Tetraclean. Freshly produced MilliQ water was used as a reference. All measurements were performed following the Wilhelmy plate technique, using a Cahn DCA-322 Dynamic Contact Angle Analyzer at the temperature of 22°C. MilliQ water, sodium hypochlorite 5.25%, and EDTA 17% had the highest surface tension, whereas those of Cetrexedin and Tetraclean has shown the lowest surface tension value. Both new irrigants, MTAD and Tetraclean, are capable of removing the smear layer. Thanks to their low surface tension, increasing the intimate contact of irrigant solutions with the dentinal walls, they may permit deeper penetration.
Lingua originale | Inglese |
---|---|
pagine (da-a) | 1091-1093 |
Numero di pagine | 3 |
Rivista | Journal of Endodontics |
Volume | 32 |
Numero di pubblicazione | 11 |
DOI | |
Stato di pubblicazione | Pubblicato - nov 2006 |