TY - JOUR
T1 - Stent malapposition, strut coverage and atherothrombotic prolapse after percutaneous coronary interventions in ST-segment elevation myocardial infarction
AU - Leone, Antonio Maria
AU - Rebuzzi, Antonio Giuseppe
AU - Burzotta, Francesco
AU - De Maria, Giovanni Luigi
AU - Gardi, Andrea
AU - Basile, Eloisa
AU - Cialdella, Pio
AU - D'AMARIO, DOMENICO
AU - Paraggio, Lazzaro
AU - Porto, Italo
AU - Aurigemma, Cristina
AU - Niccoli, Giampaolo
AU - Trani, Carlo
AU - Crea, Filippo
PY - 2019
Y1 - 2019
N2 - Aims Stent implantation in ST-segment elevation myocardial infarction (STEMI) patients can be challenging and sometimes associated with immediate and long-term suboptimal results. Stent malapposition and strut uncoverage, predictors of stent thrombosis, are frequently detected in STEMI patients at medium/long-term follow-up. Nevertheless, data at a short follow-up are missing. We aimed to assess the extent of stent malapposition and struts coverage in the subacute phase of STEMI after stent implantation in primary or rescue percutaneous coronary intervention (PCI). Methods STEMI patients undergone primary or rescue PCI and scheduled for a second coronary angiography after 2-7 days were enrolled. During the second procedure, frequency domain optical coherence tomography (FD-OCT) was performed to assess percentage of malapposed struts (MS%), percentage area of malapposition (MA%), percentage of uncovered struts (US%), percentage area of atherothrombotic prolapse (PA%) and optical coherence tomography thrombus score (OCT-TS). Results Twenty patients were included and 21 stents (19 865 struts) were evaluated. Strut uncoverage was relatively limited [US% = 11.1 (8.1-13.6) %]. Stent malapposition was observed frequently, even if at low degree [MS% = 6.4 (3.3-13.3) %, MA% = 1.80 (0.46-2.76) %] as well as atherothrombotic prolapse [PA% = 0.09 (0.00-1.06) %]. Both MA% and PA% were significantly related to residual OCT-TS (R = -0.52, P = 0.02 and R = 0.71, P < 0.001, respectively), use of thrombolysis (P = 0.001 and P = 0.004, respectively) and time elapsed from PCI to FD-OCT analysis (P = 0.001). Conclusion In the subacute phase after stenting in STEMI patients, strut uncoverage is relatively limited, while stent malapposition and atherothrombotic prolapse are common albeit limited features. Residual thrombus burden influences the degree of both stent malapposition and atherothrombotic prolapse.
AB - Aims Stent implantation in ST-segment elevation myocardial infarction (STEMI) patients can be challenging and sometimes associated with immediate and long-term suboptimal results. Stent malapposition and strut uncoverage, predictors of stent thrombosis, are frequently detected in STEMI patients at medium/long-term follow-up. Nevertheless, data at a short follow-up are missing. We aimed to assess the extent of stent malapposition and struts coverage in the subacute phase of STEMI after stent implantation in primary or rescue percutaneous coronary intervention (PCI). Methods STEMI patients undergone primary or rescue PCI and scheduled for a second coronary angiography after 2-7 days were enrolled. During the second procedure, frequency domain optical coherence tomography (FD-OCT) was performed to assess percentage of malapposed struts (MS%), percentage area of malapposition (MA%), percentage of uncovered struts (US%), percentage area of atherothrombotic prolapse (PA%) and optical coherence tomography thrombus score (OCT-TS). Results Twenty patients were included and 21 stents (19 865 struts) were evaluated. Strut uncoverage was relatively limited [US% = 11.1 (8.1-13.6) %]. Stent malapposition was observed frequently, even if at low degree [MS% = 6.4 (3.3-13.3) %, MA% = 1.80 (0.46-2.76) %] as well as atherothrombotic prolapse [PA% = 0.09 (0.00-1.06) %]. Both MA% and PA% were significantly related to residual OCT-TS (R = -0.52, P = 0.02 and R = 0.71, P < 0.001, respectively), use of thrombolysis (P = 0.001 and P = 0.004, respectively) and time elapsed from PCI to FD-OCT analysis (P = 0.001). Conclusion In the subacute phase after stenting in STEMI patients, strut uncoverage is relatively limited, while stent malapposition and atherothrombotic prolapse are common albeit limited features. Residual thrombus burden influences the degree of both stent malapposition and atherothrombotic prolapse.
KW - coverage
KW - frequency domain optical coherence tomography
KW - prolapse
KW - ST elevation myocardial infarction
KW - stent malapposition
KW - coverage
KW - frequency domain optical coherence tomography
KW - prolapse
KW - ST elevation myocardial infarction
KW - stent malapposition
UR - https://iris.uniupo.it/handle/11579/175712
U2 - 10.2459/JCM.0000000000000749
DO - 10.2459/JCM.0000000000000749
M3 - Article
SN - 1558-2035
VL - 20
JO - Journal of Cardiovascular Medicine
JF - Journal of Cardiovascular Medicine
IS - 3
ER -