Spatial resolution of limited streamer tubes with analog strip readout

  • G. D'Agostini
  • , W. De Boer
  • , A. Frenkel
  • , M. Iacovacci
  • , G. Marini
  • , B. Stella
  • , G. Catanesi
  • , F. Ruggeri
  • , G. Crosetti
  • , L. Ramello

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

We have studied the achievable spatial resolution of a streamer tube chamber with pickup strips orthogonal to the signal wires and analog readout. The measurement has been performed in real experimental conditions with 135 GeV/c muons at CERN. Using a new algorithm to determine the center of the induced charge on the strips, we have obtained for 1 cm wide strips a spatial resolution better than 500 μm after averaging over all strips. The intrinsic resolution averaged over a single strip is better than 350 μm.

Lingua originaleInglese
pagine (da-a)431-434
Numero di pagine4
RivistaNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume252
Numero di pubblicazione2-3
DOI
Stato di pubblicazionePubblicato - 1 dic 1986