Resting P d/P a and haemodynamic relevance of coronary stenosis as evaluated by fractional flow reserve

  • Giuseppe De Luca
  • , Monica Verdoia
  • , Lucia Barbieri
  • , Paolo Marino
  • , Harry Suryapranata

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

Background Fractional flow reserve (FFR) currently represents the gold standard in the evaluation of the haemodynamic relevance of coronary stenoses. However, both intracoronary and intravenous adenosine may be tolerated poorly by some patients. Therefore, considerable interest had been focused in the last few years on new adenosine-free indexes to define the haemodynamic relevance of coronary stenoses. So far, few data have been reported on resting P d/P a and its correlation with FFR as evaluated with high-dose intracoronary adenosine administration, which is the aim of the current study. Materials and methods FFR was assessed in 120 patients with 137 intermediate lesions during cardiac catheterization by a pressure-recording guidewire (PrimeWire). FFR was calculated as the ratio of the distal coronary pressure to the aortic pressure at hyperaemia. Intracoronary doses of adenosine were administered up to 720 μg as intracoronary boli. Exclusion criteria were as follows: (a) allergy to adenosine; (b) baseline bradycardia (heart rate <50 bpm); (c) hypotension (blood pressure <90 mmHg); and (d) refusal to provide signed informed consent. Results High doses of intracoronary adenosine were well tolerated, with no major side effects. Increasing doses up to 720 μg progressively decreased FFR values and increased the percentage of patients showing an FFR less than 0.80. Resting P d/P a showed good accuracy in the identification of patients with significant FFR values (<0.80) [area under the curve=0.9 (0.84-0.96), P<0.0001]. Using receiver-operating characteristic curves, we identified a threshold less than 0.93 as the best accurate cut-off value in the prediction of a positive FFR value. A value up to 0.88 was associated with a 100% positive predictive value, whereas a value of at least 0.95 was associated with a 95% negative predictive value. Conclusion This study showed that in intermediate lesions, resting P d/P a was related linearly to FFR. We identified 0.93 as the best cut-off value in the prediction of haemodynamically significant coronary stenosis as evaluated by FFR. However, cut-off values of 0.88 and 0.95 could provide the maximal predictive positive and negative values, suggesting the additional use of FFR only in patients with resting values within this range.

Lingua originaleInglese
pagine (da-a)138-144
Numero di pagine7
RivistaCoronary Artery Disease
Volume29
Numero di pubblicazione2
DOI
Stato di pubblicazionePubblicato - 2018
Pubblicato esternamente

Fingerprint

Entra nei temi di ricerca di 'Resting P d/P a and haemodynamic relevance of coronary stenosis as evaluated by fractional flow reserve'. Insieme formano una fingerprint unica.

Cita questo