Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer

  • Marco Krengli
  • , Simone Gaiano
  • , Eleonora Mones
  • , Andrea Ballarè
  • , Debora Beldì
  • , Cesare Bolchini
  • , Gianfranco Loi

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

Background: The reproducibility of patient setup for radiotherapy is based on various methods including external markers, X-rays with planar or computerized image acquisition, and, more recently, surface matching imaging. We analyzed the setup reproducibility of 16 patients affected by prostate cancer who underwent conformal radiotherapy with curative intent by using a surface image registration system. Methods: We analyzed the setup reproducibility of 16 patients affected by prostate cancer candidates for conformal radiotherapy by using a surface image registration system. At the initial setup, EPID images were compared with DRRs and a reference 3D surface image was obtained by the AlignRT system (Vision RT, London, UK). Surface images were acquired prior to every subsequent setup procedure. EPID acquisition was repeated when errors > 5 mm were reported. Results: The mean random and systematic errors were 1.2 ± 2.3 mm and 0.3 ± 3.0 mm along the X axis, 0.0 ± 1.4 mm and 0.5 ± 2.0 mm along the Y axis, and 2.0 ± 1.8 mm and -0.7 ± 2.4 mm along the Z axis respectively. The positioning error detected by AlignRT along the 3 axes X, Y, and Z exceeded the value of 5 mm in 14.1%, 2.0%, and 5.1% measurements and the value of 3 mm in 36.9%, 13.6% and 27.8% measurements, respectively. Correlation factors calculated by linear regression between the errors measured by AlignRT and EPID ranged from 0.77 to 0.92 with a mean of 0.85 and SD of 0.13. The setup measurements by surface imaging are highly reproducible and correlate with the setup errors detected by EPID. Conclusion: Surface image registration system appears to be a simple, fast, non-invasive, and reproducible method to analyze the set-up alignment in 3DCRT of prostate cancer patients.

Lingua originaleInglese
Numero di articolo9
RivistaRadiation Oncology
Volume4
DOI
Stato di pubblicazionePubblicato - 22 feb 2009

OSS delle Nazioni Unite

Questo processo contribuisce al raggiungimento dei seguenti obiettivi di sviluppo sostenibile

  1. SDG 3 - Salute e benessere
    SDG 3 Salute e benessere

Fingerprint

Entra nei temi di ricerca di 'Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer'. Insieme formano una fingerprint unica.

Cita questo