TY - JOUR
T1 - Reliability of lupus anticoagulant and anti-phosphatidylserine/prothrombin autoantibodies in antiphospholipid syndrome
T2 - A multicenter study
AU - Sciascia, Savino
AU - Radin, Massimo
AU - Cecchi, Irene
AU - Rubini, Elena
AU - Scotta, Anna
AU - Rolla, Roberta
AU - Montaruli, Barbara
AU - Pergolini, Patrizia
AU - Mengozzi, Giulio
AU - Muccini, Emanuela
AU - Baldovino, Simone
AU - Ferro, Michela
AU - Vaccarino, Antonella
AU - Mahler, Michael
AU - Menegatti, Elisa
AU - Roccatello, Dario
N1 - Publisher Copyright:
© 2019 Sciascia, Radin, Cecchi, Rubini, Scotta, Rolla, Montaruli, Pergolini, Mengozzi, Muccini, Baldovino, Ferro, Vaccarino, Mahler, Menegatti and Roccatello.
PY - 2019
Y1 - 2019
N2 - Background: Is it well-known that one of the major drawbacks of Lupus Anticoagulant (LA) test is their sensitivity to anticoagulant therapy, due to the coagulation based principle. In this study we aimed to assess the reproducibility of LA testing and to evaluate the performance of solid assay phosphatidylserine/prothrombin (aPS/PT) antibodies. Methods: We included 60 patients that fulfilled the following inclusion criteria: (I) diagnosis of thrombotic antiphospholipid syndrome (APS); (II) patients with thrombosis and (a) inconstant previous LA positivity and/or (b) positivity for antiphospholipid antibodies (aPL) at low-medium titers [defined as levels of anti-β2Glycoprotein-I or anticardiolipin (IgG/IgM) 10-30 GPL/MPL] with no previous evidence of LA positivity. aPL testing was performed blindly in 4 centers undertaking periodic external quality assessment. Results: The 60 patients enrolled were distributed as follows: 43 (71.7%) with thrombotic APS, 7 (11.7%) with thrombosis and inconstant LA positivity and 10 (16.7%) with low-medium aPL titers. Categorical agreement for LA among the centers ranged from 0.41 to 0.60 (Cohen's kappa coefficient; moderate agreement). The correlation determined at the 4 sites for aPS/PT was strong, both quantitatively (Spearman rho 0.84) and when dichotomized (Cohen's kappa coefficients = 0.81 to 1.0). Discordant (as defined by lack of agreement in ≥3 laboratories) or inconclusive LA results were observed in 27/60 (45%) cases; when limiting the analysis to those receiving vitamin K antagonist (VKA), the level of discordant LA results was as high as 75%(15/20). Conversely, aPS/PT testing showed an overall agreement of 83% (up to 90% in patients receiving VKA), providing an overall increase in test reproducibility of +28% when compared to LA, becoming even more evident (+65%) when analyzing patients on VKA. In patients treated with VKA, we observed a good correlation for aPS/PT IgG testing (Cohen's kappa coefficients = 0.81-1; Spearman rho 0.86). Conclusion: Despite the progress in the standardization of aPL testing, we observed up to 45% of overall discrepant results for LA, even higher in patients on VKA. The introduction of aPS/PT testing might represent a further diagnostic tool, especially when LA testing is not available or the results are uncertain.
AB - Background: Is it well-known that one of the major drawbacks of Lupus Anticoagulant (LA) test is their sensitivity to anticoagulant therapy, due to the coagulation based principle. In this study we aimed to assess the reproducibility of LA testing and to evaluate the performance of solid assay phosphatidylserine/prothrombin (aPS/PT) antibodies. Methods: We included 60 patients that fulfilled the following inclusion criteria: (I) diagnosis of thrombotic antiphospholipid syndrome (APS); (II) patients with thrombosis and (a) inconstant previous LA positivity and/or (b) positivity for antiphospholipid antibodies (aPL) at low-medium titers [defined as levels of anti-β2Glycoprotein-I or anticardiolipin (IgG/IgM) 10-30 GPL/MPL] with no previous evidence of LA positivity. aPL testing was performed blindly in 4 centers undertaking periodic external quality assessment. Results: The 60 patients enrolled were distributed as follows: 43 (71.7%) with thrombotic APS, 7 (11.7%) with thrombosis and inconstant LA positivity and 10 (16.7%) with low-medium aPL titers. Categorical agreement for LA among the centers ranged from 0.41 to 0.60 (Cohen's kappa coefficient; moderate agreement). The correlation determined at the 4 sites for aPS/PT was strong, both quantitatively (Spearman rho 0.84) and when dichotomized (Cohen's kappa coefficients = 0.81 to 1.0). Discordant (as defined by lack of agreement in ≥3 laboratories) or inconclusive LA results were observed in 27/60 (45%) cases; when limiting the analysis to those receiving vitamin K antagonist (VKA), the level of discordant LA results was as high as 75%(15/20). Conversely, aPS/PT testing showed an overall agreement of 83% (up to 90% in patients receiving VKA), providing an overall increase in test reproducibility of +28% when compared to LA, becoming even more evident (+65%) when analyzing patients on VKA. In patients treated with VKA, we observed a good correlation for aPS/PT IgG testing (Cohen's kappa coefficients = 0.81-1; Spearman rho 0.86). Conclusion: Despite the progress in the standardization of aPL testing, we observed up to 45% of overall discrepant results for LA, even higher in patients on VKA. The introduction of aPS/PT testing might represent a further diagnostic tool, especially when LA testing is not available or the results are uncertain.
KW - APS/PT
KW - Antiphospholipid Antibodies
KW - Antiphosphospholipid syndrome
KW - Diagnostic performance
KW - Laboratory
KW - Lupus Anticoagulant
KW - Reliability
KW - Thrombosis
UR - https://www.scopus.com/pages/publications/85063258117
U2 - 10.3389/fimmu.2019.00376
DO - 10.3389/fimmu.2019.00376
M3 - Article
SN - 1664-3224
VL - 10
JO - Frontiers in Immunology
JF - Frontiers in Immunology
IS - MAR
M1 - 376
ER -