Abstract
Biocompatible and resorbable polylactic acid (PLA) derived polymers are used for clinical applications. Antioxidant vitamin E (Vit.E) and vitamin E acetate (Vit.E Ac), a Vit.E commercial analog, were added to PLA during films preparation. Wettability, protein adsorption analysis, platelet adhesion and whole blood coagulation experiments highlighted that Vit.E incorporation improved PLA hemocompatibility. NMR analysis showed that Vit.E and Vit.E Ac blending differentially altered PLA polymer organization with Vit.E leading to the formation of microcavities, as observed by SEM analysis, while reducing surface hydrophobicity.
Lingua originale | Inglese |
---|---|
pagine (da-a) | 1527-1533 |
Numero di pagine | 7 |
Rivista | Journal of Applied Polymer Science |
Volume | 129 |
Numero di pubblicazione | 3 |
DOI | |
Stato di pubblicazione | Pubblicato - 5 ago 2013 |