T1 - Na+/H+ antiporter has different properties in human B lymphocytes according to CD5 expression and malignant phenotype
AU - Gaidano, Gianluca
AU - Caligaris‐Cappio, Federico
AU - Treves, Silvia
AU - Bussolino, Federico
AU - Pescarmona, Gianpiero
AU - Ghigo, Dario
AU - Bosia, Amalia
PY - 1991/3
Y1 - 1991/3
N2 - In B chronic lymphocytic leukemia (B‐CLL) cells, lipopolysaccharide (LPS) and phorbol esters fail to activate the plasma membrane‐associated Na+/H+ anti‐porter and, subsequently, to elicit a rise in cytosolic pH. Since these events are thought to be a prerequisite for LPS‐induced proliferation of B normal lymphocytes, we analyzed the kinetic properties of Na+/H+ antiporter in B‐CLL cells as compared to both CD5− and CD5+ normal B lymphocytes. In the present work we report that Na+/H+ exchange rate after acid loading is drastically decreased in B‐CLL cells, as compared to normal CD5− B lymphocytes, although the antiporter affinity for external Na+ and internal H+ is not significantly different in both cell populations. Kinetic data account for a reduction in the number of operating antiport units in B‐CLL. The Na+/H+ antiporter of CD5+ normal B lymphocytes exhibits both an exchange rate and an ion affinity significantly higher than that observed in both CD5+ B‐CLL cells and CD5− B normal lymphocytes, thus suggesting a possible explanation for their activated phenotype.
AB - In B chronic lymphocytic leukemia (B‐CLL) cells, lipopolysaccharide (LPS) and phorbol esters fail to activate the plasma membrane‐associated Na+/H+ anti‐porter and, subsequently, to elicit a rise in cytosolic pH. Since these events are thought to be a prerequisite for LPS‐induced proliferation of B normal lymphocytes, we analyzed the kinetic properties of Na+/H+ antiporter in B‐CLL cells as compared to both CD5− and CD5+ normal B lymphocytes. In the present work we report that Na+/H+ exchange rate after acid loading is drastically decreased in B‐CLL cells, as compared to normal CD5− B lymphocytes, although the antiporter affinity for external Na+ and internal H+ is not significantly different in both cell populations. Kinetic data account for a reduction in the number of operating antiport units in B‐CLL. The Na+/H+ antiporter of CD5+ normal B lymphocytes exhibits both an exchange rate and an ion affinity significantly higher than that observed in both CD5+ B‐CLL cells and CD5− B normal lymphocytes, thus suggesting a possible explanation for their activated phenotype.
UR - http://www.scopus.com/inward/record.url?scp=0026024230&partnerID=8YFLogxK
U2 - 10.1002/eji.1830210308
DO - 10.1002/eji.1830210308
M3 - Article
SN - 0014-2980
VL - 21
SP - 583
EP - 588
JO - European Journal of Immunology
JF - European Journal of Immunology
IS - 3
ER -