Long term experience and performance of COMPASS RICH-1

F. Tessarotto, P. Abbon, M. Alexeev, R. Birsa, P. Bordalo, F. Bradamante, A. Bressan, M. Büchele, M. Chiosso, P. Ciliberti, T. Dafni, S. Dalla Torre, S. Dasgupta, E. Delagnes, O. Denisov, V. Duic, A. Ferrero, M. Finger, M. Finger, H. FischerC. Franco, S. Gerassimov, B. Gobbo, M. Gregori, F. Herrmann, B. Ketzer, K. Königsmann, I. Konorov, F. Kunne, S. Levorato, A. Maggiora, N. Makke, A. Martin, G. Menon, D. Neyret, K. Novakova, D. Panzieri, S. Paul, F. A. Pereira, J. Polak, E. Rocco, C. A. Santos, G. Sbrizzai, P. Schiavon, S. Schopferer, M. Slunecka, F. Sozzi, L. Steiger, M. Sulc, S. Takekawa

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C4F10 radiator, a 21 m2 large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m2. It is in operation since 2002 and its performance increased thanks to progressive optimization and to a major upgrade of its photon detection system, implemented in 2006; a new upgrade is foreseen for 2016, with the use of MPGD-based photon detectors. The main characteristics of COMPASS RICH-1 components are described and the most critical aspects related to the C4F10 radiator gas system, to the mirrors and their alignment, as well as the performance of the photon detectors are presented and discussed. The response of the MWPCs and the observed evolution of the effective quantum efficiency of the CsI photocathodes is analyzed. The properties and performance of the MAPMTs with individual fused lens telescopes are presented together with the readout characteristics. The PID performance of COMPASS RICH-1 is discussed and the future upgrade program is mentioned.

Lingua originaleInglese
Numero di articoloC09011
RivistaJournal of Instrumentation
Volume9
Numero di pubblicazione9
DOI
Stato di pubblicazionePubblicato - 1 set 2014
Pubblicato esternamente

Fingerprint

Entra nei temi di ricerca di 'Long term experience and performance of COMPASS RICH-1'. Insieme formano una fingerprint unica.

Cita questo