TY - JOUR
T1 - Kinematic viscosity of unstimulated whole saliva in healthy young adults
AU - Foglio-Bonda, A.
AU - Pattarino, F.
AU - Foglio-Bonda, P. L.
PY - 2014
Y1 - 2014
N2 - OBJECTIVE: To analyze kinematic viscosity and pH of unstimulated whole saliva, evaluate possible variations after sampling, identify any gender differences and detect possible correlations between them. SUBJECTS AND METHODS: The sample consisted of sixty-four healthy young adults (37 females and 27 males, mean age 25.2 years). Saliva was collected using the spitting method at 11:00 am. Kinematic viscosity was determined with a capillary viscometer (ViscoClock, Schott-Geräte Mainz, Germany) equipped with a micro-Ubbelohde capillary. Viscosity and pH were measured at a temperature of 36°C in a thermostatic bath. Viscosity and pH data were evaluated almost simultaneously at six different times after sampling in order to identify any variations due to aging. The data were statistically analyzed using Student's t test andWilcoxon-Mann-Whitney test. RESULTS: In total sample kinematic viscosity was 1.40 cSt (SD = 0.39; RSD % = 27.81), in the male and female groups was 1.33 cSt (SD = 0.35, RSD% = 26.31) and 1.45 cSt (SD = 0.41, RSD % = 28.45) respectively; the difference was not statistically significant. Viscosity decreased exponentially as a function of time after sampling then reaching a plateau around 1.12 cSt, while the pH values increased linearly. There was a trend of pH to increase while viscosity decreases. CONCLUSIONS: Kinematic viscometry could be a valid tool to evaluate salivary viscosity. Degradation of saliva after sampling affects viscosity and slightly pH. The use of capillary viscometer to evaluate salivary aging needs more improvements. Further studies are required to investigate and explain the effects of different techniques to reduce the film forming on the air/liquid interface during measurement.
AB - OBJECTIVE: To analyze kinematic viscosity and pH of unstimulated whole saliva, evaluate possible variations after sampling, identify any gender differences and detect possible correlations between them. SUBJECTS AND METHODS: The sample consisted of sixty-four healthy young adults (37 females and 27 males, mean age 25.2 years). Saliva was collected using the spitting method at 11:00 am. Kinematic viscosity was determined with a capillary viscometer (ViscoClock, Schott-Geräte Mainz, Germany) equipped with a micro-Ubbelohde capillary. Viscosity and pH were measured at a temperature of 36°C in a thermostatic bath. Viscosity and pH data were evaluated almost simultaneously at six different times after sampling in order to identify any variations due to aging. The data were statistically analyzed using Student's t test andWilcoxon-Mann-Whitney test. RESULTS: In total sample kinematic viscosity was 1.40 cSt (SD = 0.39; RSD % = 27.81), in the male and female groups was 1.33 cSt (SD = 0.35, RSD% = 26.31) and 1.45 cSt (SD = 0.41, RSD % = 28.45) respectively; the difference was not statistically significant. Viscosity decreased exponentially as a function of time after sampling then reaching a plateau around 1.12 cSt, while the pH values increased linearly. There was a trend of pH to increase while viscosity decreases. CONCLUSIONS: Kinematic viscometry could be a valid tool to evaluate salivary viscosity. Degradation of saliva after sampling affects viscosity and slightly pH. The use of capillary viscometer to evaluate salivary aging needs more improvements. Further studies are required to investigate and explain the effects of different techniques to reduce the film forming on the air/liquid interface during measurement.
KW - Capillary viscometry
KW - Human whole saliva
KW - Kinematic viscosity
KW - Salivary pH
UR - http://www.scopus.com/inward/record.url?scp=84941120288&partnerID=8YFLogxK
M3 - Article
SN - 1128-3602
VL - 18
SP - 2988
EP - 2994
JO - European Review for Medical and Pharmacological Sciences
JF - European Review for Medical and Pharmacological Sciences
IS - 20
ER -