Salta alla navigazione principale Salta alla ricerca Salta al contenuto principale

Initial clinical experience with scanned proton beams at the Italian National Center for Hadrontherapy (CNAO)

  • J. Tuan
  • , B. Vischioni
  • , P. Fossati
  • , A. Srivastava
  • , V. Vitolo
  • , A. Iannalfi
  • , M. R. Fiore
  • , M. Krengli
  • , J. E. Mizoe
  • , R. Orecchia

Risultato della ricerca: Contributo su rivistaArticolo di reviewpeer review

Abstract

We report the initial toxicity data with scanned proton beams at the Italian National Center for Hadrontherapy (CNAO). In September 2011, CNAO commenced patient treatment with scanned proton beams within two prospective Phase II protocols approved by the Italian Health Ministry. Patients with chondrosarcoma or chordoma of the skull base or spine were eligible. By October 2012, 21 patients had completed treatment. Immobilization was performed using rigid non-perforated thermoplastic-masks and customized headrests or body-pillows as indicated. Non-contrast CT scans with immobilization devices in place and MRI scans in supine position were performed for treatment-planning. For chordoma, the prescribed doses were 74 cobalt grey equivalent (CGE) and 54 CGE to planning target volume 1 (PTV1) and PTV2, respectively. For chondrosarcoma, the prescribed doses were 70 CGE and 54 CGE to PTV1 and PTV2, respectively. Treatment was delivered five days a week in 35-37 fractions. Prior to treatment, the patients' positions were verified using an optical tracking system and orthogonal X-ray images. Proton beams were delivered using fixed-horizontal portals on a robotic couch. Weekly MRI incorporating diffusion-weighted-imaging was performed during the course of proton therapy. Patients were reviewed once weekly and acute toxicities were graded with the Common Terminology Criteria for Adverse Events (CTCAE). Median age of patients = 50 years (range, 21-74). All 21 patients completed the proton therapy without major toxicities and without treatment interruption. Median dose delivered was 74 CGE (range, 70-74). The maximum toxicity recorded was CTCAE Grade 2 in four patients. Our preliminary data demonstrates the clinical feasibility of scanned proton beams in Italy.

Lingua originaleInglese
pagine (da-a)i31-i42
RivistaJournal of Radiation Research
Volume54
Numero di pubblicazioneSUPPL.1
DOI
Stato di pubblicazionePubblicato - lug 2013

Fingerprint

Entra nei temi di ricerca di 'Initial clinical experience with scanned proton beams at the Italian National Center for Hadrontherapy (CNAO)'. Insieme formano una fingerprint unica.

Cita questo