High density spiral projection chamber (HDSPC): Design of the end-cap detectors of the obelix experiment at lear

  • M. P. Bussa
  • , L. Busso
  • , K. Erdman
  • , U. Gastaldi
  • , A. Grasso
  • , A. Maggiora
  • , S. Marcello
  • , A. Masoni
  • , D. Panzieri
  • , C. Sabev
  • , F. Tosello

Risultato della ricerca: Contributo su rivistaArticolo in rivistapeer review

Abstract

We discuss the design of a cylindrical high density projection chamber [1] that uses the spiral projection chamber [2] geometry and will instrument the end-caps of the proposed OBELIX [3] experiment at LEAR. This detector-high density spiral projection chamber (HDSPC [4])- has axial symmetry, radial drift electric field, a radiator made of converter disks alternating with drift volumes and the amplification and readout region in the outer part of the cylinder. It is equipped with FADC electronics and reconstructs in three dimensions primary ionization produced in the active volume. It features fine granularity and high angular resolution near the beam pipe and appears particularly advantageous for λ and prong detection in the forward and very forward region of storage rings and extracted beam experiments.

Lingua originaleInglese
pagine (da-a)321-324
Numero di pagine4
RivistaNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume252
Numero di pubblicazione2-3
DOI
Stato di pubblicazionePubblicato - 1 dic 1986
Pubblicato esternamente

Fingerprint

Entra nei temi di ricerca di 'High density spiral projection chamber (HDSPC): Design of the end-cap detectors of the obelix experiment at lear'. Insieme formano una fingerprint unica.