TY - JOUR
T1 - Elective Embolization of Splenic Artery Aneurysms with an Ethylene Vinyl Alcohol Copolymer Agent (Squid) and Detachable Coils
AU - Venturini, Massimo
AU - Marra, Paolo
AU - Augello, Luigi
AU - Colarieti, Anna
AU - Guazzarotti, Giorgia
AU - Palumbo, Diego
AU - Lanza, Carolina
AU - Melissano, Germano
AU - Chiesa, Roberto
AU - De Cobelli, Francesco
N1 - Publisher Copyright:
© 2020
PY - 2020/7
Y1 - 2020/7
N2 - Purpose: To report the safety and efficacy of the embolization of splenic artery aneurysms (SAAs) with coils plus ethylene vinyl alcohol copolymer (EVOH) agent. Materials and Methods: A single-center retrospective study was conducted from 2016 to 2019 to collect SAAs. Twelve asymptomatic patients (mean age, 59 years) with 15 SAAs (mean size, 23.6 mm; size range, 15–40 mm) were treated with embolization. Embolization was performed with EVOH (Squid 8/34) and fibered detachable coils. Transfemoral embolization was performed with a microcatheter to achieve a splenic artery occlusion embolizing the SAA and its efferent and afferent branches. Follow-up was based on color Doppler ultrasound at 24 hours and on computed tomography (CT) angiography at 1 (n = 12) and 6 months (n = 12) after embolization. Mean number of coils and Squid vials used for each patient, major/minor complications, technical success, 30-day clinical success, cases of revascularization/reintervention, and mortality were assessed. Technical success was defined as complete exclusion of the aneurysmal segment and cessation of blood flow into the sac. Clinical success at 1 month was based on the absence of clinical symptoms and the exclusion of aneurysm revascularization on CT angiography. Results: The mean number of coils and Squid vials was 5.75 (standard deviation [SD], 1.58; range, 3–9) and 1.41 (SD, 0.49; range, 1–2), respectively. Both technical and 30-day clinical success were 100%, with no cases of aneurysm revascularization (CT angiography performed in all patients at 1 month and 6 months and in 3 patients at 24 months). No major complications or fatal events were recorded. In terms of minor complications, 2 cases of mild pancreatitis (transient amylases increase) and 1 case of focal splenic ischemia without clinical sequelae were recorded.
AB - Purpose: To report the safety and efficacy of the embolization of splenic artery aneurysms (SAAs) with coils plus ethylene vinyl alcohol copolymer (EVOH) agent. Materials and Methods: A single-center retrospective study was conducted from 2016 to 2019 to collect SAAs. Twelve asymptomatic patients (mean age, 59 years) with 15 SAAs (mean size, 23.6 mm; size range, 15–40 mm) were treated with embolization. Embolization was performed with EVOH (Squid 8/34) and fibered detachable coils. Transfemoral embolization was performed with a microcatheter to achieve a splenic artery occlusion embolizing the SAA and its efferent and afferent branches. Follow-up was based on color Doppler ultrasound at 24 hours and on computed tomography (CT) angiography at 1 (n = 12) and 6 months (n = 12) after embolization. Mean number of coils and Squid vials used for each patient, major/minor complications, technical success, 30-day clinical success, cases of revascularization/reintervention, and mortality were assessed. Technical success was defined as complete exclusion of the aneurysmal segment and cessation of blood flow into the sac. Clinical success at 1 month was based on the absence of clinical symptoms and the exclusion of aneurysm revascularization on CT angiography. Results: The mean number of coils and Squid vials was 5.75 (standard deviation [SD], 1.58; range, 3–9) and 1.41 (SD, 0.49; range, 1–2), respectively. Both technical and 30-day clinical success were 100%, with no cases of aneurysm revascularization (CT angiography performed in all patients at 1 month and 6 months and in 3 patients at 24 months). No major complications or fatal events were recorded. In terms of minor complications, 2 cases of mild pancreatitis (transient amylases increase) and 1 case of focal splenic ischemia without clinical sequelae were recorded.
UR - http://www.scopus.com/inward/record.url?scp=85082824759&partnerID=8YFLogxK
U2 - 10.1016/j.jvir.2019.12.797
DO - 10.1016/j.jvir.2019.12.797
M3 - Article
SN - 1051-0443
VL - 31
SP - 1110
EP - 1117
JO - Journal of Vascular and Interventional Radiology
JF - Journal of Vascular and Interventional Radiology
IS - 7
ER -