T1 - Effective and organ doses in patient undergoing interventional neuroradiology procedures
T2 - A multicentre study
AU - D'Alessio, Andrea
AU - Strocchi, Sabina
AU - Dalmasso, Federico
AU - Cannillo, Barbara
AU - Matheoud, Roberta
AU - Ponzetti, Alex
AU - Aimonetto, Stefania
AU - Cernigliaro, Massimiliano
AU - Azzalin, Giulia
AU - Giorgianni, Andrea
AU - Natrella, Massimiliano
AU - Carriero, Alessandro
AU - Guzzardi, Giuseppe
AU - Brambilla, Marco
N1 - Publisher Copyright:
© 2024 Associazione Italiana di Fisica Medica e Sanitaria
PY - 2024/6
Y1 - 2024/6
N2 - Purpose: Radiation doses to adult patients submitted to cerebral angiography and intracranial aneurysms treatments were assessed by using DICOM Radiation Dose Structured Reports (RDSR) and Monte Carlo simulations. Conversion factors to estimate effective and organ doses from Kerma-Area Product (PKA) values were determined. Methods: 77 cerebral procedures performed with five angiographic equipment installed in three Italian centres were analyzed. Local settings and acquisition protocols were considered. The geometrical, technical and dosimetric data of 16,244 irradiation events (13305 fluoroscopy, 2811 digital subtraction angiography, 128 cone-beam CT) were extracted from RDSRs by local dose monitoring systems and were input in MonteCarlo PCXMC software to calculate effective and organ doses. Finally, conversion factors to determine effective and organ doses from PKA were determined. Differences between centres were assessed through statistical analysis and accuracy of dose calculation method based on conversion factors was assessed through Bland-Altman analysis. Results: Large variations in PKA (14–561 Gycm2) and effective dose (1.2–73.5 mSv) were observed due to different degrees of complexity in the procedures and angiographic system technology. The most exposed organs were brain, salivary glands, oral mucosa, thyroid and skeleton. The study highlights the importance of recent technology in reducing patient exposure (about fourfold, even more in DSA). No statistically significant difference was observed in conversion factors between centres, except for some organs. A conversion factor of 0.09 ± 0.02 mSv/Gycm2 was obtained for effective dose. Conclusions: Organ and effective doses were assessed for neuro-interventional procedures. Conversion factors for calculating effective and organ doses from PKA were provided.
AB - Purpose: Radiation doses to adult patients submitted to cerebral angiography and intracranial aneurysms treatments were assessed by using DICOM Radiation Dose Structured Reports (RDSR) and Monte Carlo simulations. Conversion factors to estimate effective and organ doses from Kerma-Area Product (PKA) values were determined. Methods: 77 cerebral procedures performed with five angiographic equipment installed in three Italian centres were analyzed. Local settings and acquisition protocols were considered. The geometrical, technical and dosimetric data of 16,244 irradiation events (13305 fluoroscopy, 2811 digital subtraction angiography, 128 cone-beam CT) were extracted from RDSRs by local dose monitoring systems and were input in MonteCarlo PCXMC software to calculate effective and organ doses. Finally, conversion factors to determine effective and organ doses from PKA were determined. Differences between centres were assessed through statistical analysis and accuracy of dose calculation method based on conversion factors was assessed through Bland-Altman analysis. Results: Large variations in PKA (14–561 Gycm2) and effective dose (1.2–73.5 mSv) were observed due to different degrees of complexity in the procedures and angiographic system technology. The most exposed organs were brain, salivary glands, oral mucosa, thyroid and skeleton. The study highlights the importance of recent technology in reducing patient exposure (about fourfold, even more in DSA). No statistically significant difference was observed in conversion factors between centres, except for some organs. A conversion factor of 0.09 ± 0.02 mSv/Gycm2 was obtained for effective dose. Conclusions: Organ and effective doses were assessed for neuro-interventional procedures. Conversion factors for calculating effective and organ doses from PKA were provided.
KW - Conversion factors
KW - Dosimetry
KW - Effective/organ dose
KW - Interventional neuroradiology
UR - http://www.scopus.com/inward/record.url?scp=85194224511&partnerID=8YFLogxK
U2 - 10.1016/j.ejmp.2024.103383
DO - 10.1016/j.ejmp.2024.103383
M3 - Article
SN - 1120-1797
VL - 122
JO - Physica Medica
JF - Physica Medica
M1 - 103383
ER -