TY - JOUR
T1 - Distal Radial Artery Approach for Invasive Blood Pressure Monitoring in Intensive Cardiac Care Unit
AU - Cumitini, Luca
AU - Giubertoni, Ailia
AU - Rossi, Lidia
AU - Patti, Giuseppe
N1 - Publisher Copyright:
© 2025 The Author(s)
PY - 2025/8/1
Y1 - 2025/8/1
N2 - Distal radial artery (dRA) is a novel vascular access site in interventional cardiology. We evaluated the use of dRA as alternative approach to standard forearm radial artery (fRA) for invasive blood pressure monitoring in Intensive Cardiac Care Unit (ICCU). This is a single-center, randomized, noninferiority trial. Patients admitted in ICCU needing invasive blood pressure monitoring were randomly allocated to dRA or fRA access site (1:1 ratio). Primary endpoint was noninferiority of dRA in the final catheterization success rate. Secondary endpoints were: first attempt success rates; arterial catheterization time; catheterization-related quality of pain; incidence of complications. A total of 250 patients were enrolled (125 in each arm). Final success rate was 95.2% in the dRA group versus 96.8% in the fRA arm (p <0.001 for noninferiority). First attempt success rates were 59.2% with dRA and 70.4% with fRA (p = 0.12). There was no difference in arterial catheterization time and catheterization-related quality of pain between the 2 arms. Entry-site complications were reduced with dRA (6.7% vs 17.4% in the fRA group; p = 0.013); this was mainly driven by decreased incidence of hematoma (0.8% vs 6.6%; p = 0.020). A numerically lower occurrence of arterial occlusion was observed with dRA (0.8% vs 4.9%; p = 0.06). In conclusion, in ICCU patients, the use of dRA to invasively monitor blood pressure is noninferior to fRA for catheterization success rates and may reduce entry-site bleeding.
AB - Distal radial artery (dRA) is a novel vascular access site in interventional cardiology. We evaluated the use of dRA as alternative approach to standard forearm radial artery (fRA) for invasive blood pressure monitoring in Intensive Cardiac Care Unit (ICCU). This is a single-center, randomized, noninferiority trial. Patients admitted in ICCU needing invasive blood pressure monitoring were randomly allocated to dRA or fRA access site (1:1 ratio). Primary endpoint was noninferiority of dRA in the final catheterization success rate. Secondary endpoints were: first attempt success rates; arterial catheterization time; catheterization-related quality of pain; incidence of complications. A total of 250 patients were enrolled (125 in each arm). Final success rate was 95.2% in the dRA group versus 96.8% in the fRA arm (p <0.001 for noninferiority). First attempt success rates were 59.2% with dRA and 70.4% with fRA (p = 0.12). There was no difference in arterial catheterization time and catheterization-related quality of pain between the 2 arms. Entry-site complications were reduced with dRA (6.7% vs 17.4% in the fRA group; p = 0.013); this was mainly driven by decreased incidence of hematoma (0.8% vs 6.6%; p = 0.020). A numerically lower occurrence of arterial occlusion was observed with dRA (0.8% vs 4.9%; p = 0.06). In conclusion, in ICCU patients, the use of dRA to invasively monitor blood pressure is noninferior to fRA for catheterization success rates and may reduce entry-site bleeding.
KW - arterial catheterization
KW - distal radial artery
KW - hemodynamic monitoring
KW - intensive cardiac care unit
KW - invasive pressure monitoring
UR - https://www.scopus.com/pages/publications/105003808154
U2 - 10.1016/j.amjcard.2025.04.005
DO - 10.1016/j.amjcard.2025.04.005
M3 - Article
SN - 0002-9149
VL - 248
SP - 16
EP - 22
JO - American Journal of Cardiology
JF - American Journal of Cardiology
ER -