TY - JOUR
T1 - Determination of perfluorochemicals in biological, environmental and food samples by an automated on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method
AU - Gosetti, Fabio
AU - Chiuminatto, Ugo
AU - Zampieri, Davide
AU - Mazzucco, Eleonora
AU - Robotti, Elisa
AU - Calabrese, Giorgio
AU - Gennaro, Maria Carla
AU - Marengo, Emilio
PY - 2010/12/10
Y1 - 2010/12/10
N2 - A rapid on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method was developed for the identification and quantitation of nine perfluorinated compounds in matrices of environmental, biological and food interest. Pre-treatment, solid phase extraction, chromatographic and mass detection conditions were optimised, in order to apply the whole methodology to the analysis of different matrices. Particular attention was devoted to the evaluation of matrix effect and the correlated phenomena of ion enhancement or suppression in mass spectrometry detection. LOD and LOQ range from 3 to 15ngL-1 and from 10 to 50ngL-1, respectively. Method detection limits (MDLs) were also calculated for each kind of matrix. The recovery, evaluated for each analyte, does not depend on analyte concentration in the explored concentration range: average R% values are always greater than 82.9%. In the whole, the results obtained for samples of river waters, blood serum, blood plasma, and fish confirm the ubiquitous presence of perfluorinated compounds, as recently denounced by many sources.
AB - A rapid on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method was developed for the identification and quantitation of nine perfluorinated compounds in matrices of environmental, biological and food interest. Pre-treatment, solid phase extraction, chromatographic and mass detection conditions were optimised, in order to apply the whole methodology to the analysis of different matrices. Particular attention was devoted to the evaluation of matrix effect and the correlated phenomena of ion enhancement or suppression in mass spectrometry detection. LOD and LOQ range from 3 to 15ngL-1 and from 10 to 50ngL-1, respectively. Method detection limits (MDLs) were also calculated for each kind of matrix. The recovery, evaluated for each analyte, does not depend on analyte concentration in the explored concentration range: average R% values are always greater than 82.9%. In the whole, the results obtained for samples of river waters, blood serum, blood plasma, and fish confirm the ubiquitous presence of perfluorinated compounds, as recently denounced by many sources.
KW - Blood sample
KW - Food sample
KW - On-line SPE
KW - Perfluorinated compounds
KW - River sample
KW - UHPLC-MS/MS
UR - https://www.scopus.com/pages/publications/78449306645
U2 - 10.1016/j.chroma.2010.10.049
DO - 10.1016/j.chroma.2010.10.049
M3 - Article
SN - 0021-9673
VL - 1217
SP - 7864
EP - 7872
JO - Journal of Chromatography A
JF - Journal of Chromatography A
IS - 50
ER -