TY - JOUR
T1 - Comparative study of different structural descriptors and variable selection approaches using partial least squares in quantitative structure-activity relationships
AU - Marengo, Emilio
AU - Carpignano, Rosarina
AU - Savarino, Piero
AU - Viscardi, Guido
PY - 1992/4
Y1 - 1992/4
N2 - Marengo, E., Carpignano, R., Savarino, P. and Viscardi, G., 1992. Comparative study of different structural descriptors and variable selection approaches using partial least squares in quantitative structure-activity relationships. Chemometrics and Intelligent Laboratory Systems, 14: 225-233. A technical property, namely fastness to light, of a series of mono-azo dyes is modelled by the partial least squares (PLS) method, using different kinds of structure descriptors: molecular descriptors calculated on the basis of partial equalization of orbital electronegativities, 13C NMR and 1H NMR experimental data, and tabulated substituent physico-chemical parameters. Two variable selection approaches in PLS are compared with traditional PLS: a backward variable elimination and a stepwise selection procedure, respectively. For this set of compounds, the best descriptors appear to be the experimental NMR data and the calculated molecular descriptors. The last ones are advantageous since previous synthesis of the compounds is not needed to obtain the value of the descriptors in order to apply the statistical model for prediction purposes. As far as the statistical approach is concerned, both the stepwise and the backward refinements appear to improve the predictive ability of PLS.
AB - Marengo, E., Carpignano, R., Savarino, P. and Viscardi, G., 1992. Comparative study of different structural descriptors and variable selection approaches using partial least squares in quantitative structure-activity relationships. Chemometrics and Intelligent Laboratory Systems, 14: 225-233. A technical property, namely fastness to light, of a series of mono-azo dyes is modelled by the partial least squares (PLS) method, using different kinds of structure descriptors: molecular descriptors calculated on the basis of partial equalization of orbital electronegativities, 13C NMR and 1H NMR experimental data, and tabulated substituent physico-chemical parameters. Two variable selection approaches in PLS are compared with traditional PLS: a backward variable elimination and a stepwise selection procedure, respectively. For this set of compounds, the best descriptors appear to be the experimental NMR data and the calculated molecular descriptors. The last ones are advantageous since previous synthesis of the compounds is not needed to obtain the value of the descriptors in order to apply the statistical model for prediction purposes. As far as the statistical approach is concerned, both the stepwise and the backward refinements appear to improve the predictive ability of PLS.
UR - http://www.scopus.com/inward/record.url?scp=0026609048&partnerID=8YFLogxK
U2 - 10.1016/0169-7439(92)80106-E
DO - 10.1016/0169-7439(92)80106-E
M3 - Article
SN - 0169-7439
VL - 14
SP - 225
EP - 233
JO - Chemometrics and Intelligent Laboratory Systems
JF - Chemometrics and Intelligent Laboratory Systems
IS - 1-3
ER -