TY - JOUR
T1 - A UPLC-MS/MS method for the simultaneous plasma quantification of all isomeric forms of the new anti-HCV protease inhibitors boceprevir and telaprevir
AU - D'Avolio, Antonio
AU - De Nicolò, Amedeo
AU - Agnesod, Danilo
AU - Simiele, Marco
AU - Mohamed Abdi, Adnan
AU - Dilly Penchala, Sujan
AU - Boglione, Lucio
AU - Cariti, Giuseppe
AU - Di Perri, Giovanni
PY - 2013/5/5
Y1 - 2013/5/5
N2 - HCV infection affects over 170 milions people in the world. Up to now standard-of-care therapy consisted in ribavirin plus interferon-α 2a or 2b. Recently, two new Direct Acting Antivirals (DAA), inhibitors of NS3 HCV protease, have been developed and approved for the routine use on HCV genotype 1 infected patients: boceprevir and telaprevir. Protease inhibitors show complex pharmacokinetics (strong metabolism of both drugs by CYP3A and drug interactions), they require a TID dosage and, furthermore, they are present in plasma patients in two different isomeric forms. In this work, we developed and validated an UPLC-tandem mass spectrometry assay method capable of monitoring the telaprevir and boceprevir concentrations in plasma, discriminating each isomer of both drugs.Blank plasma used for Standards and QCs preparation, was obtained from blood of healthy donors. The calibration curves for each isomer of telaprevir and boceprevir were linear in a range from 46.87ng/mL to 6000ng/mL and from 23.43 to 3000ng/mL, respectively (mean r2>0.998 for all analytes). QCs at three different concentration were prepared: High, Medium and Low. Each Standard, QC and patient sample was treated with a protein precipitation protocol with a solution containing acidified acetonitrile and Internal Standard (6,7-Dimethyl-2,3-di(2-pyridyl)quinoxaline). An aliquot of supernatant was diluted and then directly analyzed by reverse-phase UPLC-MS/MS. Accuracy (mean 98.47%), intra-day (mean <5.21%) and inter-day (mean <7.57%) precision for telaprevir and boceprevir quality controls fitted all FDA guidelines. All compounds resulted stable in our method conditions and the extraction procedure showed a recovery near to 100%. Finally, we tested this method by monitoring plasma concentrations in 9 HCV+ patients, for each triple combined therapy, with good results. The observed median ratio between S and R isomers for boceprevir and telaprevir were 1.22 (IQR 1.10-1.33) and 1.52 (IQR 1.21-1.67), respectively.The use of this simple assay method could be an important tool for management of HCV-1 DAAs treated patients.
AB - HCV infection affects over 170 milions people in the world. Up to now standard-of-care therapy consisted in ribavirin plus interferon-α 2a or 2b. Recently, two new Direct Acting Antivirals (DAA), inhibitors of NS3 HCV protease, have been developed and approved for the routine use on HCV genotype 1 infected patients: boceprevir and telaprevir. Protease inhibitors show complex pharmacokinetics (strong metabolism of both drugs by CYP3A and drug interactions), they require a TID dosage and, furthermore, they are present in plasma patients in two different isomeric forms. In this work, we developed and validated an UPLC-tandem mass spectrometry assay method capable of monitoring the telaprevir and boceprevir concentrations in plasma, discriminating each isomer of both drugs.Blank plasma used for Standards and QCs preparation, was obtained from blood of healthy donors. The calibration curves for each isomer of telaprevir and boceprevir were linear in a range from 46.87ng/mL to 6000ng/mL and from 23.43 to 3000ng/mL, respectively (mean r2>0.998 for all analytes). QCs at three different concentration were prepared: High, Medium and Low. Each Standard, QC and patient sample was treated with a protein precipitation protocol with a solution containing acidified acetonitrile and Internal Standard (6,7-Dimethyl-2,3-di(2-pyridyl)quinoxaline). An aliquot of supernatant was diluted and then directly analyzed by reverse-phase UPLC-MS/MS. Accuracy (mean 98.47%), intra-day (mean <5.21%) and inter-day (mean <7.57%) precision for telaprevir and boceprevir quality controls fitted all FDA guidelines. All compounds resulted stable in our method conditions and the extraction procedure showed a recovery near to 100%. Finally, we tested this method by monitoring plasma concentrations in 9 HCV+ patients, for each triple combined therapy, with good results. The observed median ratio between S and R isomers for boceprevir and telaprevir were 1.22 (IQR 1.10-1.33) and 1.52 (IQR 1.21-1.67), respectively.The use of this simple assay method could be an important tool for management of HCV-1 DAAs treated patients.
KW - Boceprevir
KW - HCV
KW - Plasma
KW - Telaprevir
KW - UPLC-MS/MS
UR - http://www.scopus.com/inward/record.url?scp=84875271297&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2013.02.025
DO - 10.1016/j.jpba.2013.02.025
M3 - Article
SN - 0731-7085
VL - 78-79
SP - 217
EP - 223
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
ER -