Skip to main navigation Skip to search Skip to main content

TomoDirect: An efficient means to deliver radiation at static angles with tomotherapy

  • Pierfrancesco Franco
  • , Paola Catuzzo
  • , Domenico Cante
  • , Maria Rosa La Porta
  • , Piera Sciacero
  • , Giuseppe Girelli
  • , Valeria Casanova Borca
  • , Massimo Pasquino
  • , Gianmauro Numico
  • , Santi Tofani
  • , Teodoro Meloni
  • , Umberto Ricardi
  • , Franca Ozzello

Research output: Contribution to journalArticlepeer-review

Abstract

Aims and background. The TomoTherapy Hi-Art II system is able to deliver dynamic intensity-modulated radiation therapy within a helical geometry providing robust conformality and modulation, abrupt dose falloff, and reliable accuracy. A new upgrade named TomoDirect was introduced recently, allowing delivery of radiation at discrete angles with a fixed gantry. We present our preliminary clinical experience with TomoDirect. Methods. Three specific clinical contexts were chosen for the implementation of TomoDirect, namely palliation of bonemetastasis pain (BP), whole brain radiation therapy for intracranial secondary lesions (WBRT), and adjuvant whole breast radiation therapy after conservative surgery for early stage breast cancer (AWBRT). After appropriate positioning, planning CT, contouring, and plan generation, all patients were treated with the TomoDirect upgrade of the TomoTherapy Hi-Art II system with different doses and fractionation according to clinical decision-making. Results. Between May and December 2010, 41 patients were treated with TomoDirect. Eighteen patients were treated for BP (mainly vertebral metastases) with a predominant posterior field arrangement. Seven patients were treated for WBRT (multiple brain lesions) with a parallel-opposed latero-lateral approach and 16 patients were treated for conventionally fractionated AWBRT mainly with a 2-field tangential approach. Radiation treatments were generally well tolerated and the acute toxicity was mild. Conclusions. While helical tomotherapy allows the delivery of very sophisticated treatment plans, in certain anatomical sites and clinical contexts where the number of beamdirections is constrained and supposed not to affect plan quality, TomoDirect might be an efficient means to deliver radiation at static angles with consistent dosimetric and clinical results.

Original languageEnglish
Pages (from-to)498-502
Number of pages5
JournalTumori
Volume97
Issue number4
DOIs
Publication statusPublished - 2011
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bone metastasis
  • Brain metastasis
  • Breast cancer
  • TomoDirect
  • Tomotherapy

Fingerprint

Dive into the research topics of 'TomoDirect: An efficient means to deliver radiation at static angles with tomotherapy'. Together they form a unique fingerprint.

Cite this