The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients

Alexandra Beurton, Jean Louis Teboul, Francesco Gavelli, Filipe Andre Gonzalez, Valentina Girotto, Laura Galarza, Nadia Anguel, Christian Richard, Xavier Monnet

Research output: Contribution to journalArticlepeer-review

Abstract

Background: A passive leg raising (PLR) test is positive if the cardiac index (CI) increased by > 10%, but it requires a direct measurement of CI. On the oxygen saturation plethysmographic signal, the perfusion index (PI) is the ratio between the pulsatile and the non-pulsatile portions. We hypothesised that the changes in PI could predict a positive PLR test and thus preload responsiveness in a totally non-invasive way. Methods: In patients with acute circulatory failure, we measured PI (Radical-7) and CI (PiCCO2) before and during a PLR test and, if decided, before and after volume expansion (500-mL saline). Results: Three patients were excluded because the plethysmography signal was absent and 3 other ones because it was unstable. Eventually, 72 patients were analysed. In 34 patients with a positive PLR test (increase in CI ≥ 10%), CI and PI increased during PLR by 21 ± 10% and 54 ± 53%, respectively. In the 38 patients with a negative PLR test, PI did not significantly change during PLR. In 26 patients in whom volume expansion was performed, CI and PI increased by 28 ± 14% and 53 ± 63%, respectively. The correlation between the PI and CI changes for all interventions was significant (r = 0.64, p < 0.001). During the PLR test, if PI increased by > 9%, a positive response of CI (≥ 10%) was diagnosed with a sensitivity of 91 (76-98%) and a specificity of 79 (63-90%) (area under the receiver operating characteristics curve 0.89 (0.80-0.95), p < 0.0001). Conclusion: An increase in PI during PLR by 9% accurately detects a positive response of the PLR test. Trial registration: ID RCB 2016-A00959-42. Registered 27 June 2016.

Original languageEnglish
Article number19
JournalCritical Care
Volume23
Issue number1
DOIs
Publication statusPublished - 18 Jan 2019
Externally publishedYes

Keywords

  • Cardiac index
  • Fluid responsiveness
  • Oxygen saturation
  • Perfusion index
  • Volume expansion

Fingerprint

Dive into the research topics of 'The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients'. Together they form a unique fingerprint.

Cite this