This paper describes the performance of a prototype timing detector, based on 50//m thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and bias voltage is investigated in this paper. A timing precision from 30 ps to 100 ps (RMS), depending on the pixel capacitance, has been measured at a bias voltage of 180 V.
| Original language | English |
|---|---|
| Article number | P03024 |
| Journal | Journal of Instrumentation |
| Volume | 12 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - Mar 2017 |
Keywords
- Analogue electronic circuits
- Performance of high energy physics detectors
- Solid state detectors
- Timing detectors