To analyze the inter-observer variability and the potential impact of 18F-fluorodeoxyglucose FDG)-positron emission tomography/computed tomography (PET/CT) imaging for target volume delineation in preoperative radiotherapy of rectal cancer. Gross tumor volume (GTV) and clinical target volume (CTV) in 2 cases of rectal cancer were contoured by 10 radiation oncologists, 5 on CT and 5 on PET/CT images. Resulting volumes were analyzed by coef-ficient of variation (CV) and concordance index (CI). Mean GTV was 120 cc ± 20.4 cc in case A and 119 cc ± 35.7 cc in case B. Mean CTV was 723 cc ± 147.5 cc in case A and 739 cc ± 195.6 cc in case B. CV was lower and CI was similar or higher across the observers contouring GTV on PET/CT. CTV variability was less influenced by the use of PET/CT. PET/CT may allow reducing inter-observer variability in GTV delineation.
| Original language | English |
|---|---|
| Pages (from-to) | 393-398 |
| Number of pages | 6 |
| Journal | Technology in Cancer Research and Treatment |
| Volume | 9 |
| Issue number | 4 |
| DOIs | |
| Publication status | Published - Aug 2010 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Observer variability
- PET/CT
- Radiotherapy
- Rectal cancer
- Treatment planning