Skip to main navigation Skip to search Skip to main content

Multicentric evaluation of analytical performances digital morphology with respect to the reference methods by manual optical microscopy

  • Giorgio Da Rin
  • , Anna Benegiamo
  • , Anna Maria Di Fabio
  • , Francesco Dima
  • , Sara Francione
  • , Alessandra Fanelli
  • , Luca Germagnoli
  • , Maria Lorubbio
  • , Alessandro Marzoni
  • , Rachele Pajola
  • , Silvia Pipitone
  • , Roberta Rolla
  • , Michela Seghezzi
  • , Maria Del Carmen Baigorria Vaca
  • , Andrea Bartolini
  • , Sabrina Buoro

Research output: Contribution to journalArticlepeer-review

Abstract

Aims Optical microscopic (OM) evaluation of peripheral blood (PB) cells is still a crucial step of the laboratory haematological workflow. The morphological cell analysis is time-consuming and expensive and it requires skilled operator. To address these challenges, automated image-processing systems, as digital morphology (DM), were developed in the last few years. The aim of this multicentre study, performed according to international guidelines, is to verify the analytical performance of DM compared with manual OM, the reference method. Methods Four hundred and ninety PB samples were evaluated. For each sample, two May Grunwald-stained and Giemsa-stained smears were performed and the morphological evaluation of cells was analysed with both DM and OM. In addition, the assessment times of both methods were recorded. Results Comparison of DM versus OM methods was assessed with Passing-Bablok and Deming fit regression analysis: slopes ranged between 0.17 for atypical, reactive lymphocytes and plasma cells (LY(AT)) and 1.24 for basophils, and the intercepts ranged between -0.09 for blasts and 0.40 for LY(AT). The Bland-Altman bias ranged between -6.5% for eosinophils and 21.8% for meta-myemielocytes. The diagnostic agreement between the two methods was 0.98. The mean of assessment times were 150 s and 250 s for DM and OM, respectively. Conclusion DM shows excellent performance. Approximately only 1.6% of PB smears need the OM revision, giving advantages in terms of efficiency, standardisation and assessment time of morphological analysis of the cells. The findings of this study may provide useful information regarding the use of DM to improve the haematological workflow.

Original languageEnglish
Pages (from-to)377-385
Number of pages9
JournalJournal of Clinical Pathology
Volume74
Issue number6
DOIs
Publication statusPublished - 2021

Fingerprint

Dive into the research topics of 'Multicentric evaluation of analytical performances digital morphology with respect to the reference methods by manual optical microscopy'. Together they form a unique fingerprint.

Cite this