Abstract
Penetrating foreign bodies occurring after maxillofacial injuries are a diagnostic challenge for the trauma surgeon. Different materials and various sites of penetration in the maxillofacial region are described in the literature. We present the peculiar course of a patient with an endoral retained foreign body after a penetrating facial injury. The diagnostic pitfall in this type of trauma is highlighted owing to the hyperdensity of the foreign body that, at the computed tomographic (CT) axial scan, simulated a vestibular cortical fracture of the mandibular body and deceived both the radiologist and the surgeon.
| Original language | English |
|---|---|
| Pages (from-to) | e91-e93 |
| Journal | Journal of Craniofacial Surgery |
| Volume | 23 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - Mar 2012 |
| Externally published | Yes |
Keywords
- Facial trauma
- Foreign body
- Mandibular fracture
Fingerprint
Dive into the research topics of 'Mandibular Symphyseal Fracture Simulated by a Foreign Body in the Chin'. Together they form a unique fingerprint.Cite this