Skip to main navigation Skip to search Skip to main content

Magnetic resonance angiography of the origins of the supraaortic arteries: Comparison of single and double volume acquisition 3D time of flight

  • A. Carriero
  • , N. Magarelli
  • , F. Padovano
  • , M. Baratto
  • , R. Fossaceca
  • , L. Bonomo

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: The authors have optimized the technique of Magnetic Resonance Angiography (MR-angio) in the study of the origins of the supraaortic arteries. Methods: Twenty healthy volunteers, mean age 21.5, were studied with MR-angio of the origins of the supraaortic arteries; a 1 T superconductive magnet (Impact) with body coil was used. All the volunteers were studied using Time of flight (TOF), and two acquisition techniques: single volume FISP (fast imaging with steady-state precession) 3D TONE (tilted optimized non-saturating excitation) and double volume FISP 3D TONE with 30% overlapping. The images were acquired on the axial plane following the positioning of three pre-saturation pulses. Results: Regarding the visualization of the different components of the origins of the supraaortic arteries, a statistical analysis was worked out using the Mann Whitney test (p < 0.05); there was no statistically significant difference between two techniques. Regarding the visualization of the various segments (origin, 1/3 proximal, 1/3 middle, 1/3 distal), although the double volume did on the one hand allow a better visualization of the more distal vascular components (statistically significant difference), on the other it induced the presence of artefacts with decreased the quality of the image as a whole. Discussion: In our experience TOF 3D technique with TONE and single volume has well identified the origin of the vertebral arteries, while, in several cases, TOF 3D technique with TONE and double volume did not permit the visualization of the origin of the vertebral arteries due to the presence of the artefacts from overlapping. Conclusion: From our experience we have established that the TOF 3D technique with TONE and single volume makes it possible to obtain MR-angio of a high diagnostic quality in a short time (10-15 mn).

Original languageEnglish
Pages (from-to)62-68
Number of pages7
JournalJournal of Neuroradiology
Volume23
Issue number2
Publication statusPublished - Sept 1996
Externally publishedYes

Keywords

  • arteries
  • carotid
  • magnetic resonance vascular studies
  • subclavian
  • vertebral

Fingerprint

Dive into the research topics of 'Magnetic resonance angiography of the origins of the supraaortic arteries: Comparison of single and double volume acquisition 3D time of flight'. Together they form a unique fingerprint.

Cite this