Skip to main navigation Skip to search Skip to main content

Intensity-modulated adjuvant whole breast radiation delivered with static angle tomotherapy (TomoDirect): A prospective case series

  • Pierfrancesco Franco
  • , Michele Zeverino
  • , Fernanda Migliaccio
  • , Piera Sciacero
  • , Domenico Cante
  • , Valeria Casanova Borca
  • , Paolo Torielli
  • , Cecilia Arrichiello
  • , Giuseppe Girelli
  • , Gianmauro Numico
  • , Maria Rosa La Porta
  • , Santi Tofani
  • , Umberto Ricardi

Research output: Contribution to journalReview articlepeer-review

Abstract

Purpose To report the 2-year outcomes of whole breast intensity-modulated radiotherapy (IMRT) after conserving surgery for early breast cancer (EBC) delivered with static angle tomotherapy (TomoDirect) (TD). Methods A prospective cohort of 120 EBC patients underwent whole breast IMRT with TD between 2010 and 2012. Radiation was delivered to a conventionally fractionated whole breast total dose of 50 Gy with TD, followed by a sequential conventionally fractionated tumor bed boost dose of 10-16 Gy with helical tomotherapy (HT). Clinical endpoints include acute and late toxicity, cosmesis, quality of life and local control. Results Median follow-up was 24 months (range 12-36 months); maximum detected acute skin toxicity was G0 22 %; G1 63 %; G2 12 % and G3 3 %. Predictors of acute dermatitis were as follows: volume of the whole breast minus boost volume receiving 105, 110 and 115 % of prescription dose, whole breast and boost volume, breast thickness and soft tissue thickness. Late skin toxicity was mild with no[G2 events. Cosmesis was good/excellent in 91.7 %of patients and fair/poor in 8.3 %. Quality of life was preserved over time, but for fatigue, transiently increased. Conclusion Adjuvant whole breast IMRT delivered sequentially with both TD and HT provides consistent clinical results. An observed unintended excessive dose outside the tumor bed might increase acute toxicity and eventually affect long-term clinical endpoints. The incorporation of the boost dose within the whole breast phase employing a simultaneous integrated boost (SIB) approach might mitigate this issue.

Original languageEnglish
Pages (from-to)1927-1936
Number of pages10
JournalJournal of Cancer Research and Clinical Oncology
Volume139
Issue number11
DOIs
Publication statusPublished - Nov 2013
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Adjuvant whole breast radiotherapy
  • IGRT
  • IMRT
  • Radiotherapy
  • TomoDirect
  • Tomotherapy

Fingerprint

Dive into the research topics of 'Intensity-modulated adjuvant whole breast radiation delivered with static angle tomotherapy (TomoDirect): A prospective case series'. Together they form a unique fingerprint.