Skip to main navigation Skip to search Skip to main content

Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope

  • Pietro Palmisano
  • , Federico Guerra
  • , Vittorio Aspromonte
  • , Gabriele Dell'Era
  • , Pier Luigi Pellegrino
  • , Mattia Laffi
  • , Carlo Uran
  • , Silvana De Bonis
  • , Michele Accogli
  • , Antonio Dello Russo
  • , Giuseppe Rocco Salvatore Patti
  • , Francesco Santoro
  • , Antonella Torriglia
  • , Gerardo Nigro
  • , Antonio Bisignani
  • , Giovanni Coluccia
  • , Giulia Stronati
  • , Vincenzo Russo
  • , Ernesto Ammendola

Research output: Contribution to journal › Article › peer-review

Abstract

BackgroundImplantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of traumatic syncopal recurrence during ILR monitoring in this specific patient setting are lacking.Research design and methodsProspective, multicentre registry enrolling consecutive patients undergoing ILR insertion for unexplained, recurrent, traumatic syncope. In a proportion of enrolled patients, remote monitoring (RM) was used for device follow-up. The risk of traumatic and non-traumatic syncopal recurrences during ILR observation were prospectively assessed.ResultsA total of 483 consecutive patients (68 +/- 14 years, 59% male) were enrolled. During a median follow-up of 18 months, a final diagnosis was reached in 270 patients (55.9%). The risk of syncopal and traumatic syncopal recurrence was of 26.5 and 9.3%, respectively. RM significantly reduced the time to diagnosis (19.7 +/- 10.3 vs. 22.1 +/- 10.8 months; p=0.015) and was associated with a significant reduction in the risk of syncope recurrence of 48% (p<0.001), and of traumatic syncope recurrence of 49% (p=0.018).ConclusionsILR monitoring is effective and safe in patients with unexplained, recurrent, traumatic syncope. RM reduces the time to diagnosis and significantly reduces the risk of traumatic and non-traumatic syncopal relapses.
Original languageEnglish
Pages (from-to)45-54
Number of pages10
JournalExpert Review of Medical Devices
Volume20
Issue number1
DOIs
Publication statusPublished - 2023

Keywords

  • Implantable loop recorder
  • insertable cardiac monitor
  • remote monitoring
  • traumatic syncope
  • unexplained syncope

Fingerprint

Dive into the research topics of 'Effectiveness and safety of implantable loop recorder and clinical utility of remote monitoring in patients with unexplained, recurrent, traumatic syncope'. Together they form a unique fingerprint.

Cite this