Skip to main navigation Skip to search Skip to main content

Comparative Effectiveness of Biosimilar, Reference Product and Other Erythropoiesis-Stimulating Agents (ESAs) Still Covered by Patent in Chronic Kidney Disease and Cancer Patients: An Italian Population-Based Study

  • Ylenia Ingrasciotta
  • , Francesco Giorgianni
  • , Ilaria Marcianò
  • , Jenny Bolcato
  • , Roberta Pirolo
  • , Alessandro Chinellato
  • , Valentina Ientile
  • , Domenico Santoro
  • , Armando A. Genazzani
  • , Angela Alibrandi
  • , Andrea Fontana
  • , Achille P. Caputi
  • , Gianluca Trifirò

Research output: Contribution to journalArticlepeer-review

Abstract

Background Since 2007 biosimilars of erythropoiesis-stimulating agents (ESAs) are available on the Italian market. Very limited post-marketing data exist on the comparative effectiveness of biosimilar and originator ESAs. Aim This population-based study was aimed to compare the effects of biosimilars, reference product and other ESAs still covered by patent on hemoglobinemia in chronic kidney disease (CKD) and cancer patients in a Local Health Unit (LHU) from Northern Italy. Methods A retrospective cohort study was conducted during the years 2009-2014 using data from Treviso LHU administrative database. Incident ESA users (no ESA dispensing within 6 months prior to treatment start, i.e. index date (ID)) with at least one hemoglobin measurement within one month prior to ID (baseline Hb value) and another measurement between 2nd and 3rd month after ID (follow-up Hb value) were identified. The strength of the consumption (as total number of defined daily dose (DDD) dispensed during the follow-up divided by days of follow-up) and the difference between follow-up and baseline Hb values [delta Hb (ΔHb)] were evaluated. Based on Hb changes, ESA users were classified as non-responders (ΔHb≤0 g/dl), responders (0<<enty>Delta;Hb≤2 g/dl), and highly responders (ΔHb>2 g/ dl). A multivariate ordinal logistic regression model to identify predictors for responsiveness to treatment was performed. All analyses were stratified by indication for use and type of dispensed ESA at ID. Results Overall, 1,003 incident ESA users (reference product: 252, 25.1%; other ESAs covered by patent: 303, 30.2%; biosimilars: 448, 44.7%) with CKD or cancer were eligible for the study. No statistically significant difference in the amount of dose dispensed during the follow-up among biosimilars, reference product and other ESAs covered by patent was found in both CKD and cancer. After three months from treatment start, all ESAs increased Hb values on average by 2g/dl. No differences in ΔHb as well as in frequency of non-responders, responders and highly responders among different types of ESAs were observed in both indications of use. Overall, around 15-20% of ESA users were non-responders. Strength of treatment, but no type of dispensed ESAs was found to be predictor of responsiveness to treatment. Conclusions No difference on the effects on hemoglobinemia among users of either biosimilars or reference product or ESAs covered by patent was observed in a general population from Northern Italy, despite a comparable dispensed dose of the different ESAs during the first three months of treatment.

Original languageEnglish
Article numbere0155805
JournalPLoS ONE
Volume11
Issue number5
DOIs
Publication statusPublished - May 2016

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Comparative Effectiveness of Biosimilar, Reference Product and Other Erythropoiesis-Stimulating Agents (ESAs) Still Covered by Patent in Chronic Kidney Disease and Cancer Patients: An Italian Population-Based Study'. Together they form a unique fingerprint.

Cite this