Skip to main navigation Skip to search Skip to main content

Angio-RM con tecnica "a bolo di contrasto" del rene trapiantato con apparecchiatura a basso campo (0,5 T): Accuratezza diagnostica, sensibilità e specificità delle immagini e delle ricostruzioni nella valutazione delle complicazioni vascolari

Translated title of the contribution: Contrast-bolus MR angiography of the transplanted kidney with a low-field (0.5-T) scanner: Diagnostic accuracy, sensitivity and specificity of images and reconstructions in the evaluation of vascular complications

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose. This study was performed to assess the feasibility, interobserver variability, sensitivity, specificity and diagnostic accuracy of raw data and postprocessed images from a low-field (0.5-T) magnetic resonance (MR) unit in evaluating vascular complications of kidney grafts. Materials and methods. We enrolled 49 patients undergoing MR angiography (MRA) for a clinical suspicion of renal artery stenosis. The raw data, maximum intensity projections (MIP) and multiplanar reconstruction (MPR) image sets were evaluated independently. We calculated the number and degree of stenosis, and sensitivity, specificity and accuracy for MIP, MPR and raw data image sets, together with interobserver variability. Results. Interobserver agreement was substantial. There were no differences among the MIP and MPR algorithms and raw data images for the detection of stenosis. Raw data images were more accurate in quantifying the severity of stenosis, with higher sensitivity (75% vs. 62.5%), equal specificity and higher diagnostic accuracy (75% vs. 71.43%). Conclusions. Contrast-enhanced MRA, even with a low-field (0.5-T) unit, is a feasible, sensitive and accurate technique for the study of the renal arteries of the transplanted kidney.

Translated title of the contributionContrast-bolus MR angiography of the transplanted kidney with a low-field (0.5-T) scanner: Diagnostic accuracy, sensitivity and specificity of images and reconstructions in the evaluation of vascular complications
Original languageItalian
Pages (from-to)1026-1035
Number of pages10
JournalRadiologia Medica
Volume112
Issue number7
DOIs
Publication statusPublished - Oct 2007

Fingerprint

Dive into the research topics of 'Contrast-bolus MR angiography of the transplanted kidney with a low-field (0.5-T) scanner: Diagnostic accuracy, sensitivity and specificity of images and reconstructions in the evaluation of vascular complications'. Together they form a unique fingerprint.

Cite this