Abstract

There are no data on procedure-related bleeding outcome with non-vitamin K antagonist anticoagulants (NOACs) versus vitamin K antagonist anticoagulants (VKAs) in patients with atrial fibrillation (AF) undergoing cardiac implantable electronic device (CIED) intervention. Our aim was to evaluate whether NOACs have a safety benefit even in terms of fewer hemorrhagic complications at the site of CIED implant. Consecutive AF patients receiving NOACs or VKAs at the time of CIED procedure were included in this observational, retrospective, and monocentric investigation. Primary endpoint was the incidence of post-intervention pocket hematoma. A total of 311 patients were enrolled, 146 on NOACs, and 165 on VKAs. The incidence of pocket hematoma was 3.4% in the NOAC versus 13.3% in the VKA group (p = 0.002). Primary outcome-free survival at 30-days was 96.6% in patients on NOACs and 86.0% in those on VKAs (p = 0.019). Multivariate analysis, adjusted by propensity-score calculation of inverse-probability-weighting, showed a significantly lower oc-currence of pocket hematoma in patients receiving NOACs versus VKAs (HR 0.35, 95% CI 0.13–0.96, p = 0.042). Such NOACs benefit was confirmed versus patients on VKAs without peri-procedural bridging with low-molecular-weight heparin (HR 0.34, 95% CI 0.11–0.99, p = 0.048). The incidence of pocket infection, surgical pocket evacuation, ischemic events, and major bleeding complications at 30 days (secondary endpoints) was similar in the two groups. In conclusion, our data suggest that, among patients with AF undergoing implantable cardiac defibrillator or pacemaker intervention, the use of NOACs versus VKAs may be associated with significant reduction of post-procedural pocket hematoma, regardless of bridging with low-molecular-weight heparin in the VKA group. These results are hypothesis generating and need to be confirmed in a specific randomized study.

Original languageEnglish
Article number986
JournalJournal of Clinical Medicine
Volume11
Issue number4
DOIs
Publication statusPublished - 1 Feb 2022

Keywords

  • Cardiac implantable device
  • Non-vitamin K antagonist anticoagulant
  • Oral anticoagulation
  • Pocket hematoma
  • Vitamin K antagonist